MomentumCTN.FI · RO · HU

Setting up an OxyPro™ VS1 room

Where to place the chamber and compressor unit, how much space to leave, and how to make a soft shell hyperbaric room calm and practical.

A soft shell chamber asks little of a building. The OxyPro™ VS1 needs a normal socket, a flat floor and a quiet room. Getting the details right makes the difference between a storage room with a chamber in it and a service clients pay for.

What goes in the room

Item Size Weight
Chamber L 2300 × W 1000 × H 1200 mm 46 kg
Compressor unit L 766 × W 350 × H 750 mm 110 kg

The compressor unit supplies air at 72 L/min and oxygen at 10 L/min, and also dehumidifies.

Space

We estimate about 6 m². A room of 3 × 2 metres holds the chamber along one wall with the compressor unit at its foot or side. Leave a clear metre along the entry side so clients can get in and out without hurry.

Power

1100 W on 220 V. A normal socket near the compressor unit is enough.

Noise

The compressor runs throughout the session. Place it as far from the client's head as the hoses allow. If the room has a cupboard or alcove with ventilation, that is the ideal home for it. Never enclose it without airflow.

Air

The compressor draws in room air. Keep the room clean, ventilated and free of strong smells. Do not store cleaning chemicals beside it.

Light and mood

Clients lie inside for about an hour. Soft, indirect lighting and a comfortable room temperature matter. Avoid a bright ceiling light directly above the chamber window.

The floor

Flat, clean and free of sharp objects. A soft shell chamber rests on the floor, so sweep before each inflation.

Access

Clients step down into a low chamber. A small stool or bench beside it helps, as does a hook for clothes and a shelf for shoes.

Moving it

The chamber deflates and weighs 46 kg. The compressor unit is 110 kg. Moving the system to another room is a two person job that takes minutes, which is useful if your space changes use during the week.

Staff position

A trained member of staff must be nearby for every session. Place a chair where they can see the chamber window and the controls.

A checklist

  1. Normal socket within reach of the compressor unit.
  2. About 6 m² of clear, flat floor.
  3. Ventilation, and no strong smells.
  4. Dimmable lighting.
  5. Bench, hooks and a shelf.
  6. A seat for the operator.

Send us a photo of the room on WhatsApp and we will suggest a layout. CTN devices are CE marked wellness equipment, not medical devices.